In Karnataka, anyone proposing to build a high-rise building must get a No Objection Certificate from the Karnataka State Fire and Emergency Services (KSFES). The Karnataka Fire Force Act, 1964, as amended in 2023, defines a high-rise as a building 21 metres or more in height, whatever its use. That is roughly a ground floor plus six floors. Buildings between 15 m and 21 m do not need the KSFES NOC under this definition, but Bengaluru's zoning rules still require them to meet the National Building Code's fire and life-safety provisions. Since 9 November 2026, KSFES accepts NOC applications only through the state's Unified Land Management System (ULMS).
Updated 18 November 2026. We read the amendment's text (Section 13(3) and (4) and the 21 m explanation), the KSFES website and its apartment checklist, the January 2026 zoning amendment, and a 7 November 2026 report on a draft to raise the line to 24 m. The 15 m figure that some pages still quote comes from older rules; the Act's own definition is 21 m.
Is a fire NOC mandatory in Karnataka?
- Section 13(3), inserted by the Karnataka Fire Force (Amendment) Act, 2023: any person proposing to construct a high-rise building shall obtain an NOC from KSFES.
- Section 13(4): KSFES follows the National Building Code 2016 on fire and life safety and collects the prescribed fee.
- Explanation: a high-rise building is one of 21 metres or more in height, irrespective of occupancy, as defined in NBC 2016.
- The amendment is deemed to be in force from 24 March 2023. It replaced an ordinance issued earlier that year.
- Height is measured under NBC clause 2.10: from the average ground level around the building to the terrace of the last livable floor, for flat roofs (KSFES A-4 checklist).
15 m or 21 m: which height rule applies in Bangalore?
For the KSFES NOC, 21 m. The 2023 amendment wrote that number into the Act. The 15 m figure survives in two places. First, Bengaluru's January 2026 zoning amendment requires buildings of 15 to 21 m, including stilts, to comply with NBC fire and life-safety requirements (Cyril Amarchand Mangaldas, summarising notification UDD/235/MNJ 2025(E)). Second, KSFES's own checklist for apartments, drawn from NBC, requires fire-tender access for buildings above 15 m and says buildings of 15 m and above should generally have fire lifts.
So a 5- or 6-floor building of 15–21 m has fire-safety duties without a KSFES NOC. Treat it like any building and check the fire equipment on site.
Will the threshold change to 24 m?
Possibly. The Urban Development Department published a draft notification in the Karnataka Gazette on 4 November 2026 to raise the high-rise threshold in Bengaluru's zoning regulations from 21 m to 24 m, on the fire department's recommendation, with 30 days for objections (The Realty Today, 7 November 2026). It is a draft and not in force. It amends the zoning regulations; whether the Fire Force Act's 21 m definition will also change has not been announced. Until a final notification, 21 m applies.
How do you get a fire NOC in Bangalore?
- From 9 November 2026, NOC applications are accepted only through ULMS (ulms.karnataka.gov.in), per a notice on the KSFES website.
- KSFES lists three linked services: the NOC (at plan stage), the clearance certificate (after construction) and the renewal of the clearance certificate.
- The KSFES A-4 checklist asks for building details (number of buildings, floors including basements, height, site area) and for the fire prevention, firefighting and evacuation measures, all to NBC 2016.
- Fee: Section 13(4) provides for a prescribed fee, but we found no published schedule. Calcguru says the same (August 2026). Ask the KSFES helpdesk: 080-22971512, KSFESHELPDESK@GMAIL.COM.
- Fire cess: Calcguru reports that the Karnataka Fire Force (Amendment) Act, 2025 levies a 1% surcharge on the property tax of newly built multi-storeyed buildings, collected with property tax. We could not open the gazette text today.
What fire rules apply to tall apartment buildings?
From KSFES's Group A-4 (residential apartments) checklist, which follows NBC 2016:
- Access road: the street in front at least 12 m wide, joining another street of at least 12 m. No dead-end road, except for residential buildings up to 30 m.
- Fire tender access for buildings above 15 m: at least one-third of the perimeter for floor area under 10,000 sq m, and half the perimeter above that, on a driveway at least 6.0 m wide with a 9.0 m turning radius.
- Fire lifts: generally for buildings of 15 m and above, for at least 8 passengers, with an emergency switch at ground level.
- Wet risers, sprinklers, alarms and refuge areas follow NBC Part 4 by height and floor area.
How do flat buyers check fire NOC and safety?
- Measure the height first: a building of 21 m or more needs the KSFES NOC; ask for its number and date.
- Before possession, ask for KSFES's clearance certificate and check the OC; how the two documents differ: Occupancy Certificate vs Completion Certificate in Bengaluru: What to Demand Before You Take Possession.
- In an older complex, ask the association for the latest renewal of the clearance certificate.
- Walk the site: a 6 m fire-tender driveway kept clear, working hydrants and wet risers, fire lift, refuge floors where required.
- Full document list: Documents Required to Buy a Flat in Bangalore: 2026 Checklist. Choosing a floor: High Floor vs Low Floor: Which Apartment to Choose.
- Independent houses of stilt plus three floors are capped at 12 m on small plots and do not reach the 21 m line: Setback Rules in Bangalore for 30x40 and 40x60 Sites (2026).